Electric Power Insulation Equipments

Your Professional Electric Power Insulation Equipments Supplier

DZ SAFETY is a large-scale comprehensive enterprise that integrates research and development (R&D), production, and sales of safety protection components. We provide a full range of high-quality metal safety components for full-body harnesses, including market-leading fall arrest harness components that combine superior quality with competitive pricing. Our primary products include forged safety locking ladder snap hooks, climbing carabiners, safety buckles, and safety rings.

Professional Team

We possess an advanced design and R&D team specializing in precision punching and forging technologies. All employees are highly experienced and capable of developing precision-engineered products with consistently high-end quality standards.

Global Sales Market

Our company collaborates with enterprises in more than 80 countries and regions, including major markets such as the United Kingdom, France, Italy, Spain, South Africa, Japan, South Korea, Russia, Thailand, and Vietnam.

 

Rich Experience

With over 15 years of specialization in safety harness accessories, we have established ourselves as industry leaders in this field.

Product Certification

Our main products have obtained CE certification, ensuring compliance with stringent European safety standards.

 

 
 
Specifications of Electric Power Insulation Equipments

 

Name

Working at heights insulation harness snap hook

Fall protection insulation harness snap hook

Fall arrest insulation Harness d ring

WET

630g

266g

165g

SIZE

250*125mm gate 55mm

161*60mm,Gate 21mm

88*76.1mm,inner width52mm

Min. Breaking load

5000lbs/23kN

5000lbs/23kN

5000lbs/23kN

Meets

ANSI

ANSI

ANSI

 

Types of Electric Power Insulation Equipments

 

 

The electric power insulation equipments produced by our company mainly include the following types: 

Insulated Rescue Hook

Insulated Rescue Hook, also known as Live Line Rescue Tool or Electrical Insulation Hook, is primarily used in emergency rescue operations, especially in environments where electrical hazards exist.

 

Dielectric Snap Hook

Polymer coated metal snap hook, it's completely electrically insulated. A highly resistant outer coating dielectric snap hook, with a dielectric breakdown voltage of 9kV.

 

High Voltage Protective 25kv Insulation Hand Glove

The 25kv insulation hand glove is a reliable tool for electrical workers to protect their hands from high voltage exposure. It is commonly used in power plants, substations, and other industries where electrical hazards are present.

 

 

productcate-650-450

Benefits of Using Electric Power Insulation Equipments

 

Increased Safety: Protects against thermal injuries.

 

Enhanced Comfort: Maintains hand warmth or coolness, reducing fatigue.

 

Enhanced productivity: Helps employees to concentrate on duties free from discomfort.

 

Compliance with Regulations: Meets occupational safety requirements.

 

Applications of Electric Power Insulation Equipments
 
 
 

Maintenance and Repair

During routine maintenance or repair work on electrical systems, circuits may need to remain energized to avoid disrupting critical operations or processes. Electric power insulation equipments allow electricians to safely work on these live circuits.

 
 

Troubleshooting

When diagnosing and locating faults or issues within an electrical system, it may be necessary to work on energized components. Electric power insulation equipments provide the necessary protection during this troubleshooting process.

 
 

Emergency Repairs

In the event of an electrical emergency, such as a power outage or equipment failure, electric power insulation equipments enable electricians to safely perform repairs or temporary fixes on live circuits until a complete shutdown can be arranged.

 
 

Testing and Verification

When testing or verifying the functionality of electrical systems, electric power insulation equipments allow for safe interactions with live circuits without the need for a complete power-down.

 

 

Common Rated Voltages of Electric Power Insulation Equipments

1,000V AC or 1,500V DC: Suitable for most residential and light commercial electrical work.

10,000V AC or 14,000V DC: Designed for higher-voltage applications, such as industrial or utility work.

20,000V AC or 28,000V DC: Used in high-voltage environments, like power transmission and distribution systems.

 

Precautions for Use of Electric Power Insulation Equipments
 

Tool Selection

Guidance on selecting the appropriate electric power insulation equipments based on voltage levels, work environment, and task requirements.

 

Inspection Procedures

Step-by-step instructions on how to inspect electric power insulation equipments for damage or wear before each use, and criteria for determining when tools should be removed from service.

 

Proper Usage Techniques

Hands-on training on the correct techniques for using different types of electric power insulation equipments, while following safe work practices and body positioning.

 

Limitations and Precautions

Understanding the limitations of electric power insulation equipments and the importance of integrating their use with other safety measures, such as lockout/tagout procedures, PPE, and safe work practices.

 

Incident Reporting and Investigation

Procedures for reporting and investigating incidents involving electric power insulation equipments, as well as procedures for removing damaged tools from service and replacing them.

 

 

Storage Precautions for Electric Power Insulation Equipments

Drying: Electric power insulation equipments should be thoroughly dried before storage, as moisture can potentially degrade the insulating material over time.

 

Storage Conditions: Tools should be stored in a clean, dry environment, away from direct sunlight, extreme temperatures, or exposure to chemicals or solvents that could potentially damage the insulation.

 

Storage Cases or Bags: Using designated storage cases or bags can help protect electric power insulation equipments from damage and keep them organized and easily accessible.

productcate-500-400

 

 

Packaging and Shipping

 

 

Packaging

We choose good quality cartons for packaging, if you have customized needs, please communicate with us before delivery.

Shipping

We will help you to choose the best shipping way according to your detail requirements. By sea, by air, or by express, etc.

We offer multiple delivery methods that can be selected according to customer needs, including T/T, L/C, D/P, VISA, PAYPAL,

 

 

Our Factory

 

 

Hebei Dongzhou Lifting Equipment Co., Ltd. is located in Cangzhou City, Hebei Province, China. It has a strong technical force, complete processing equipment, and complete testing methods. It has more than 100 products, covering industries such as fall protection, electrical insulation protection, fire protection. After thousands of improvements, the quality is stable and the reliability is high.

productcate-1-1
productcate-1-1
productcate-1-1
productcate-1-1
productcate-1-1
productcate-1-1
productcate-1-1
productcate-1-1

 

 

Our Certifications

 
productcate-644-884
productcate-644-884
productcate-644-884
productcate-644-884
productcate-644-884

 

 

FAQ

 

Q: What are the primary functions of insulation in electrical equipment?

A: Insulation prevents direct contact between conductors and other components, blocking electrical current leakage, ensuring safety, and maintaining system efficiency. It also protects against environmental factors like moisture and contaminants.

Q: What must you not do when storing insulating gloves?

A: Proper storage means that gloves must not be folded and need to be kept out of excessive heat, sunlight, humidity, ozone, and any chemical or substance that could damage the rubber.

Q: How long are insulated gloves good for?

A: As long as the gloves pass the test every 6 months, they are acceptable for use. There is a requirement to visually inspect and air test the gloves before first use each day.

Q: How to use an electrical rescue hook?

A: Separate the victim from the source. Don't touch the victim, even with a non-conducting instrument, if the electricity hasn't been shut off. Once you're sure there is no current, use your Safety Rescue Hook to separate the victim from the source.

Q: What is an improper use of the snap hook?

A: Snap hooks are only designed to be loaded in a specific way, and connecting to unapproved anchorage points could cause them to become loaded incorrectly and fail. Some organizations avoid misusing rebar snap hooks by simply prohibiting their use in their facility.

As one of the leading electric power insulation equipments manufacturers in China, we warmly welcome you to buy or wholesale discount electric power insulation equipments from our factory. All customized products are with high quality and low price. For pricelist and quotation, contact us now.

Suitable For 50mm Width safety Harness webbing rope, Yellow Silver Zinc Plated Finish Rebar Hook, Safety Webbing Buckle